Reciprocity Calibration System Type 5998

Reciprocity Calibration Apparatus Type 5998 is an easily operated high-precision and high-stability laboratory instrument designed for precision calibration of condenser microphones by the reciprocity method.

The apparatus determines the electrical transfer impedance as described in IEC 1094 – 2, and can calibrate microphones which fulfil IEC 1094 – 1, Laboratory Standard Microphones.

The system allows measurements to be done semi-automatically, but Type 5998 can be used in combination with the other instruments to do manual reciprocity calibration measurements, though of course these take longer than if using computer controlled measurement sequences.

Type 5998 includes all the couplers and adaptors necessary for manual or automatic calibration. In addition, calibration requires the use of an external voltmeter, filter and generator. These are available from Brüel & Kjær as Reciprocity Calibration System Type 9699, described on the first pages of this Product Data Sheet.



Reciprocity calibration of microphones has mainly been used only in a few laboratories and at few frequencies, often only 250 Hz and 1 kHz. With the introduction of Reciprocity Calibration System Type 9699, all of this changes.

Primary calibration laboratories, calibration service centres and larger organisations with their own calibration facilities now have the opportunity to make faster and more accurate electrical transfer impedance measurements of coupled microphones. This makes multiple-frequency calibration a feasible option, since the time required per step is greatly reduced. The included measurement and calculation software is one of the benefits of using Type 9699. The software controls the system via an IEEE–488 bus, and afterwards handles the calculations. This makes the measurement task semi-automatic and greatly reduces the risk of making errors during calculation of final calibration results.

Reciprocity Calibration System Type 9699 is based on Reciprocity Calibration Apparatus Type 5998, together with a set of standard hardware components. More details about Type 5998 are found on page 5. Included with the system are two PC programs, one to control measurements and the other to handle the sensitivity calculations according to IEC 1094 – 2. A reciprocity calibration system similar to Type 9699 has been used for several years by DPLA, the Danish Primary Laboratory of Acoustics*, and has also been sold to other national laboratories.